Add to Cart
Metal Building Material steel Semi Grouting Coupler
Main Features
1. Use solid 45# carbon or 50# steel as raw material.
2. Tensile Strenth is more than 540MPa.
3. There are 2 types, one is full grouting coupler(connected with rebar by concrete-based grouting material), and the other is semi/half grouting coupler(which one end is connected by threaded screw, and the other is connected by concrete-based grouting material).
Material | Steel |
Certificate | ISO9001 |
Packaging | Carton &wooden boxes, nylon bags and as customer’s special requests |
Application | Grout sleeves are used in precast column or precast wall. |
Parameters of semi-grouting sleeve-Building | ||||||||||||
Grout Sleeve Model | Bar Diameter | Connecting bar diameter | Outer Diameter | Length | Minimum hole diameter of steel bar insertion opening at grouting end of sleeve | Grout Hole Center Position | The Hole Location Of The Outflow Slurry | Grout end connecting steel bar Twisting depth | Internal thread nominal diameter | Internal thread pitch | Internal thread profile angle | Internal thread depth |
GTB4J-12 | Φ12 | Φ12/Φ10 | 34 | 140 | 23 | 28 | 94 | 96 -116 | 12.6 | 2 | 75° | 14 |
GTB4J—14 | Φ14 | Φ14/Φ12 | 36 | 156 | 25 | 30 | 110 | 112 -132 | 14.6 | 2 | 75° | 15 |
GTB4J-16 | Φ16 | Φ16/Φ14 | 39 | 174 | 28 | 30 | 126 | 128 -148 | 16.6 | 2.5 | 75° | 18 |
GTB4J-18 | Φ18 | Φ18/Φ16 | 41 | 193 | 29 | 35 | 142 | 144-164 | 18.5 | 2.5 | 75° | 21 |
GTB4J-20 | Φ20 | Φ20/Φ18 | 43 | 211 | 30 | 40 | !58 | 160-180 | 20.5 | 2.5 | 75° | 23 |
GTB4J-22 | Φ22 | Φ22/Φ20 | 46 | 230 | 32 | 40 | 174 | 176-196 | 22.5 | 2.5 | 75° | 25 |
GTB4J-25 | Φ25 | Φ25/Φ22 | 52 | 260 | 36 | 40 | 198 | 200-220 | 25.7 | 3 | 75° | 28 |
GTB4J-28 | Φ28 | Φ28/Φ25 | 60 | 292 | 43 | 40 | 228 | 224-244 | 28.7 | 3 | 75° | 31 |
GTB4J-32 | Φ32 | Φ32/Φ28 | 66 | 330 | 47 | 40 | 263 | 256-275 | 32.7 | 3 | 75° | 35 |
Note: 1. The bottom dimension in the table is the value of the sleeve raw material that meets the mechanical performance requirements of No. 45 steel in GB/T699-2015 (the measured yield strength and ultimate strength should not be less than J355-2015 Rebar Sleeve Grouting Connection Application Technology The standard specified in the regulations), the minimum size that can be selected when the sleeve manufacturer has a good level of quality control. 2. The minimum size of the measured sleeve should be measured in at least two directions, and the minimum value should be used for judgment. 3. The customer's special customized sleeve must meet the mechanical performance parameters (strength requirements) of the sleeve as a premise, and the size can be flexibly controlled. |
Parameters of semi-grouted sleeves- bridge connection | ||||||||
Grout Sleeve Model | Bar Diameter | Outer Diameter | Inner Diameter | Length | Grout Hole Center Position | The Hole Location Of The Outflow Slurry | On-site Construction Reinforcement Insertion Depth | Factory Installed Rebar Insertion Depth |
GTB4J-32 | Φ32 | 70 | 53 | 394 | 28 | 94 | 96 -116 | 12.6 |
GTB4J-36 | Φ36 | 78 | 57 | 440 | 30 | 110 | 112 -132 | 14.6 |
GTB4J-40 | Φ40 | 89 | 65 | 480 | 30 | 126 | 128 -148 | 16.6 |